(Peer-Reviewed) The incidence and predictors of high-degree atrioventricular block in patients with bicuspid aortic valve receiving self-expandable transcatheter aortic valve implantation
Yuan-Weixiang OU 欧袁伟翔 ¹ ², Jing-Jing HE 何婧婧 ², Xuan ZHOU 周轩 ¹ ³, Guo-Yong LI ², Yan-Biao LIAO 廖延标 ², Xin WEI 魏薪 ², Yong PENG 彭勇 ¹ ², Yuan FENG 冯沅 ¹ ², Mao CHEN 陈茂 ¹ ²
¹ Department of Cardiac Catheterization Laboratory, West China Hospital, Sichuan University, Sichuan, China
中国 四川 四川大学 华西医院 心导管室
² Department of Cardiology, West China Hospital, Sichuan University, Sichuan, China
中国 四川 四川大学 华西医院 心脏内科
³ Department of Radiology, West China Hospital, Sichuan University, Sichuan, China
中国 四川 四川大学 华西医院 放射科
BACKGROUND
The high-degree atrioventricular block (HAVB) in patients with bicuspid aortic valve (BAV) treated with transcatheter aortic valve implantation (TAVI) remains high. The study aims to explore this poorly understood subject of mechanisms and predictors for HAVB in BAV self-expandable TAVI patients.
METHODS
We retrospectively included 181 BAV patients for analysis. Using computed tomography data, the curvature of ascending aorta (AAo) was quantified by the angle (AAo angle) between annulus and the cross-section at 35 mm above annulus (where the stent interacts with AAo the most). The valvular anatomy and leaflet calcification were also characterized.
RESULTS
The 30-day HAVB rate was 16.0% (median time to HAVB was three days). Type-1 morphology was found in 79 patients (43.6%) (left- and right-coronary cusps fusion comprised 79.7%). Besides implantation below membrane septum, large AAo angle [odds ratio (OR) = 1.08, P = 0.016] and type-1 morphology (OR = 4.97, P = 0.001) were found as the independent predictors for HAVB. Together with baseline right bundle branch block, these predictors showed strong predictability for HAVB with area under the cure of 0.84 (sensitivity = 62.1%, specificity = 92.8%). Bent AAo and calcified raphe had a synergistic effect in facilitating high implantation, though the former is associated with at-risk deployment (device implanted above annulus + prothesis pop-out, versus straight AAo: 9.9% vs. 2.2%, P = 0.031).
CONCLUSIONS
AAo curvature and type-1 morphology are novel predictors for HAVB in BAV patients following self-expandable TAVI. For patients with bent AAo or calcified raphe, a progressive approach to implant the device above the lower edge of membrane septum is favored, though should be done cautiously to avoid pop-out.
Triplet exciton harvesting via TADF in hafnium chlorides array scintillator screen enables ultrahigh-resolution X-ray imaging
Jun'an Lai, Yi Ye, Xu Liu, Sijun Cao, Shiji Zhou, Wenxia Zhang, Kang An, Peng He, Tingming Jiang, Xiaosheng Tang, Rui Zhou, Dong Zhang
Opto-Electronic Advances
2026-06-08
Vacancy oscillating mode in amorphous binary oxide film by terahertz time domain spectroscopy
Huan Liu, Haiyun Huang, Heng Yu, Zhi Gong, Fei Yu, Zheng Zhang, Zhiyong Tan, Juncheng Cao, Haiyun Liu, Kan-Hao Xue, Xiangshui Miao, Yan Liu, Yue Hao, Genquan Han, Qihua Xiong
Opto-Electronic Advances
2026-06-08
Emerging optical techniques for sorting and detection of chiral particles
Yuzhi Shi, Chengfeng Li, Xiaolei Lin, Wenwen Xue, Chengxing Lai, Tao He, Qinghua Song, Zhanshan Wang, Yulan Wang, Din Ping Tsai, Xinbin Cheng, Haidong Zou
Opto-Electronic Advances
2026-06-08
Phonon-assisted absorption photoconductive switch
Zhao Wang, Lixin Zhang, Lu Cheng, Danwen Zhang, Yu Lu, Naiji Zhang, Xin Zhang, Duanyang Chen, Zhan Sui, Hongji Qi, Wei Zheng
Opto-Electronic Science
2026-05-25
Photonic spiking reinforcement learning for intelligent routing
Shuiying Xiang, Yonghang Chen, Ling Zheng, Zhicong Tu, Xintao Zeng, Mengting Yu, Shuai Wang, Yahui Zhang, Xingxing Guo, Weitao Pan, Yue Hao
Opto-Electronic Science
2026-05-25