Year
Month

(Peer-Reviewed) Ferritin as a diagnostic, differential diagnostic, and prognostic marker for immune-related adverse events
Weihong Zhang 张维红 ¹, Yuan Meng ¹, Lin Yang 杨琳 ², Meng Shen 沈梦 ¹, Li Zhou 周莉 ¹, Runmei Li 李润美 ¹, Yang Wang 王扬 ¹, Weijiao Du 杜伟娇 ¹, Yanjuan Xiong 熊艳娟 ¹, Ying Han 韩颖 ¹, Xinwei Zhang 张新伟 ¹, Liang Liu 刘亮 ¹, Xiubao Ren 任秀宝 ¹
¹ Department of Immunology and Biotherapy, Key Laboratory of Cancer Immunology and Biotherapy, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin, Tianjin's Clinical Research Center for Cancer, Tianjin 300060, China
中国 天津 天津市肿瘤免疫与生物治疗重点实验室 天津医科大学肿瘤医院肿瘤研究所 国家肿瘤临床研究中心 天津市肿瘤防治重点实验室 国家肿瘤临床医学研究中心
² State Key Laboratory of Experimental Hematology, Peking Union Medical College, Institute of Hematology and Blood Diseases Hospital, Chinese Academy of Medical Sciences, Tianjin 300020, China
中国 天津 北京协和医学院 实验血液学国家重点实验室 中国医学科学院血液学研究所
Objective

Distinguishing immune-related adverse events (irAEs) caused by immune checkpoint inhibitors (ICIs) from the AEs caused by chemotherapy, targeted therapy, or infection is highly difficult. This study offers new insights into evaluating the diagnosis, differential diagnostic, and prognostic value of ferritin for irAEs induced by ICIs.

Methods

From December 1, 2018, to April 1, 2019, we examined 318 patients with malignant tumors who received serum ferritin monitoring. The cohort comprised 231 patients treated with PD-1 inhibitor or combination with chemotherapy, and 87 patients treated with chemotherapy. Of the 231 patients, 90 had irAEs (irAE group), 70 had non-irAEs (non-irAE group), 67 had no AEs (no irAE-non irAE group), and 4 had unclassified AEs. In the 87 patients, 60 had AEs (AE group), and 27 had no AEs (no AE group). Statistical analyses were conducted with nonparametric Mann-Whitney tests.

Results

At the onset of AEs in the irAE group, ferritin (normal range, 35–150 µg/L) rose to a median of 927 µg/L (range, 117–17,825 µg/L) from 86 µg/L at baseline (range, 29–421 µg/L) (P < 0.001). Ferritin levels at the onset of AEs in the irAE group were significantly higher than those in the non-irAE group (median, 81 µg/L; range, 32–478 µg/L) (P < 0.001) and the AE group (median,
103 µg/L; range, 23–712 µg/L) (P < 0.001). After treatment in the irAE group, ferritin ntinuously decreased to a normal range in recovered patients, showed no significant changes in stable patients, and continued to rise in patients who died.

Conclusions

Ferritin can be used as a diagnostic, differential diagnostic, and prognostic marker for irAEs in patients treated with ICIs.
Ferritin as a diagnostic, differential diagnostic, and prognostic marker for immune-related adverse events_1
Ferritin as a diagnostic, differential diagnostic, and prognostic marker for immune-related adverse events_2
Ferritin as a diagnostic, differential diagnostic, and prognostic marker for immune-related adverse events_3
Ferritin as a diagnostic, differential diagnostic, and prognostic marker for immune-related adverse events_4
  • Harmonic heterostructured pure Ti fabricated by laser powder bed fusion for excellent wear resistance via strength-plasticity synergy
  • Desheng Li, Huanrong Xie, Chengde Gao, Huan Jiang, Liyuan Wang, Cijun Shuai
  • Opto-Electronic Advances
  • 2025-09-25
  • Strong-confinement low-index-rib-loaded waveguide structure for etchless thin-film integrated photonics
  • Yifan Qi, Gongcheng Yue, Ting Hao, Yang Li
  • Opto-Electronic Advances
  • 2025-09-25
  • Flicker minimization in power-saving displays enabled by measurement of difference in flexoelectric coefficients and displacement-current in positive dielectric anisotropy liquid crystals
  • Junho Jung, HaYoung Jung, GyuRi Choi, HanByeol Park, Sun-Mi Park, Ki-Sun Kwon, Heui-Seok Jin, Dong-Jin Lee, Hoon Jeong, JeongKi Park, Byeong Koo Kim, Seung Hee Lee, MinSu Kim
  • Opto-Electronic Advances
  • 2025-09-25
  • Dual-frequency angular-multiplexed fringe projection profilometry with deep learning: breaking hardware limits for ultra-high-speed 3D imaging
  • Wenwu Chen, Yifan Liu, Shijie Feng, Wei Yin, Jiaming Qian, Yixuan Li, Hang Zhang, Maciej Trusiak, Malgorzata Kujawinska, Qian Chen, Chao Zuo
  • Opto-Electronic Advances
  • 2025-09-25
  • Phase matching sampling algorithm for sampling rate reduction in time division multiplexing optical fiber sensor system
  • Junhui Wu, Zhilin Xu, Yi Shi, Yurong Liang, Qizhen Sun
  • Opto-Electronic Technology
  • 2025-09-18
  • Three-dimensional integrated optical fiber devices: emergence and applications
  • Tingting Yuan, Xiaotong Zhang, Shitai Yang, Donghui Wang, Libo Yuan
  • Opto-Electronic Technology
  • 2025-09-18
  • Femtosecond laser micro/nano-processing via multiple pulses incubation
  • Jingbo Yin, Zhenyuan Lin, Lingfei Ji, Minghui Hong
  • Opto-Electronic Technology
  • 2025-09-18
  • All-optical digital logic and neuromorphic computing based on multi-wavelength auxiliary and competition in a single microring resonator
  • Qiang Zhang, Yingjun Fang, Ning Jiang, Anran Li, Jiahao Qian, Yiqun Zhang, Gang Hu, Kun Qiu
  • Opto-Electronic Science
  • 2025-08-28
  • Fast step heterodyne light-induced thermoelastic spectroscopy gas sensing based on a quartz tuning fork with high-frequency of 100 kHz
  • Yuanzhi Wang Ying He, Shunda Qiao, Xiaonan Liu, Chu Zhan, Xiaoming Duan, Yufei Ma
  • Opto-Electronic Advances
  • 2025-08-28
  • Advances and new perspectives of optical systems and technologies for aerospace applications: a comprehensive review
  • Sandro Oliveira, Jan Nedoma, Radek Martinek, Carlos Marques
  • Opto-Electronic Advances
  • 2025-08-25
  • Dynamic spatial beam shaping for ultrafast laser processing: a review
  • Cyril Mauclair, Bahia Najih, Vincent Comte, Florent Bourquard, Martin Delaigue
  • Opto-Electronic Science
  • 2025-08-25
  • Aberration-corrected differential phase contrast microscopy with annular illuminations
  • Yao Fan, Chenyue Zheng, Yefeng Shu, Qingyang Fu, Lixiang Xiong, Guifeng Lu, Jiasong Sun, Chao Zuo, Qian Chen
  • Opto-Electronic Science
  • 2025-08-25



  • Anti-anaphylactic potential of benzoylpaeoniflorin through inhibiting HDC and MAPKs from Paeonia lactiflora        A chloride efflux transporter, BIG RICE GRAIN 1, is involved in mediating grain size and salt tolerance in rice
    About
    |
    Contact
    |
    Copyright © PubCard