(Peer-Reviewed) Contrast-enhanced ultrasound as a valuable imaging modality for characterizing testicular lesions
Jie Yu 于洁 ¹, Xin-Hui Jiang 江鑫辉 ², Lian-Fang Du 杜联芳 ¹, Min Bai 白敏 ¹, Zhao-Jun Li 李朝军 ¹, Qiu-Sheng Shi 史秋生 ¹, Qi Jiang 蒋琪 ³, Fan Li 李凡 ¹
¹ Department of Ultrasound, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 201620, China
中国 上海 上海交通大学医学院 上海市第一人民医院 超声科
² Department of Medical Ultrasound, Shanghai Baoshan Hospital of Integrated Traditional Chinese and Western Medicine, Shanghai 201999, China
中国 上海 上海市宝山区中西医结合医院 超声科
³ Department of Urology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200080, China
中国 上海 上海交通大学医学院 上海市第一人民医院 泌尿科
Asian Journal of Andrology
, 2021-09-14
Abstract
Contrast-enhanced ultrasound (CEUS) is a new form of ultrasound (US) that can dynamically display microvessels in a highly sensitive manner. The purpose of this study was to investigate the efficacy of CEUS for characterizing testicular lesions in comparison with conventional US. Forty-seven patients with testicular lesions were enrolled.
The histopathology results revealed that 31 cases were neoplastic (11 cases of seminomas, 8 nonseminomatous germ cell tumors, 8 lymphomas, 2 Leydig cell tumors, and 2 nonspecific tumors), and 16 cases were nonneoplastic (8 cases of infarctions, 3 epidermoid cysts, and 5 inflammation). The indicators of shallow lobulated morphology and cystic-solid echogenicity on conventional US were suggestive of germ cell tumors. More indicators on CEUS were found to be useful for characterizing testicular lesions. All the neoplastic lesions showed hyperenhancement on CEUS. Moreover, germ cell tumors presented with heterogeneous enhancement (73.7%, 14/19), a twisted blood vessel pattern, rapid wash-in and wash-out, and peripheral rim hyperenhancement signs. Lymphoma was characterized by nonbranching linear vessel patterns (87.5%, 7/8), rapid wash-in and slow wash-out.
In nonneoplastic lesions, infarction and epidermoid cysts showed no enhancement, and abscesses were observed with marginal irregular enhancement. The sensitivity, specificity, and accuracy of CEUS for differentiating between neoplastic and nonneoplastic lesions were 100%, 93.8%, and 97.9%, respectively, and these values were higher than those for conventional US (90.3%, 62.5%, and 80.9%, respectively). CEUS can sensitively reflect the microvascular perfusion in testicular lesions and offers high accuracy for characterizing them.
Embedded solar adaptive optics telescope: achieving compact integration for high-efficiency solar observations
Naiting Gu, Hao Chen, Ao Tang, Xinlong Fan, Carlos Quintero Noda, Yawei Xiao, Libo Zhong, Xiaosong Wu, Zhenyu Zhang, Yanrong Yang, Zao Yi, Xiaohu Wu, Linhai Huang, Changhui Rao
Opto-Electronic Advances
2025-05-27
Wearable photonic smart wristband for cardiorespiratory function assessment and biometric identification
Wenbo Li, Yukun Long, Yingyin Yan, Kun Xiao, Zhuo Wang, Di Zheng, Arnaldo Leal-Junior, Santosh Kumar, Beatriz Ortega, Carlos Marques, Xiaoli Li, Rui Min
Opto-Electronic Advances
2025-05-27
Integrated photonic polarizers with 2D reduced graphene oxide
Junkai Hu, Jiayang Wu, Di Jin, Wenbo Liu, Yuning Zhang, Yunyi Yang, Linnan Jia, Yijun Wang, Duan Huang, Baohua Jia, David J. Moss
Opto-Electronic Science
2025-05-22
Structural color: an emerging nanophotonic strategy for multicolor and functionalized applications
Wenhao Wang, Long Wang, Qianqian Fu, Wang Zhang, Liuying Wang, Gu Liu, Youju Huang, Jie Huang, Haoyuan Zhang, Fuqiang Guo, Xiaohu Wu
Opto-Electronic Science
2025-04-25